Fixed Temp. Incubator from small to large capacity, high functional and best-selling for long years
Features of Low Temperature Incubator (Programmable, Peltier Cooling) (IJ101)
Fixed Temp. Incubator from small to large capacity, high functional and best-selling for long years
Features of Low Temperature Incubator (Programmable, Peltier Cooling) (IJ101)
Highly functional fixed temp. incubator with varying capacity.
A compact model ideal for preserving samples and for constant temperature testing
Feature
A CFC-free, low-vibration model with a cooler equipped with peltier elements
Feature
Uses a programmable temperature controller (IJ201/300)
Feature
Has a convenient pre-reset temperature function ( as an option)
Feature
Air jacket can be attached as an option
Feature
Two units can be stacked by the stacking support (Option)
Feature
The IJ101W observation window uses environmentally friendly glass made from combination of energy-saving pair glsass and half-tempered glass, which prevents wasteful heat loss
Feature
A sliding mounting table can be provided with the IJ300 model ( as an option) for convenience when setting a microshaker inside and when adding / removing samples. The service outlet on the side of the unit does not require any wiring. A shaker cannot be set in the IJ101W model.
Feature
Safety has been enhanced with the addition of a self-diagnostic function, an overheat prevention device and an over-current circuit breaker.
Model | IJ101 |
---|---|
Type | Forced convection |
Operating Temperature Range | 5~60℃(at room temp.25℃) |
Temp. Control Accuracy | ±0.3℃(at 37℃) |
Temp. Distribution Accuracy | ±1.0℃(at 37℃) |
Time to Max. Temp. | 20~60℃ 60min. |
Time to Lowest Temp. | 20~5℃ 100min. |
Interior | Stainless steel |
Heater | Mica heater 120W |
Condenser | Peltiert element, Forced radiation type |
Temp. Control Method | PID |
Operation Function | Program operation (30 steps x 1, 15 steps x 2, 10 steps x 3), Fixed operation, Quick auto-stop, Auto-stop, Auto-start operation |
Additional Functions | Calibration off-set, Key-lock function, Auto recovery function at power failure |
Sensor | Double sensor: Platinum resistance Pt 100Ω (Temp. controller), K-thermocouple(Overheat preventor) |
Safety Functions | Self-diagnostic function(Temp. sensor error, heater failure, SSR short-circuit, Auto overheat), Overheat prevention(IJ201/301), Liquid pressure overheat preventor, Over-current ELB, Main relay error |
Shelf Loading Capacity | Approx. 5kg/ shelf |
Shelf Step | 7 steps |
Accessories | Shelf(Stainless punching metal) 2pcs., Shelf support 4 pcs., Receiver for drain 1pc. |
Internal dimensions(W×D×H mm) | 250×250×250mm |
External dimensions(W×D×H mm) | 350×399×565mm |
Remarks(dimensions) | 15.6L |
Power Source | AC115V/AC220V single phase with step-down transformer |
Weight | 20kg |